The proper design of cogeneration plants requires the choice of the technologies that best fits the ratio between heating and power loads. In this paper, a dynamical procedure of selecting and dimensioning a cogeneration plant, using deep and detailed energy, exergy and economic analysis of the entire production process of a frozen food production factory is proposed. The results highlight that a design method, based on a dynamic simulation, optimizes the energy efficiency of the food processing plant involved in the experimental test. Indeed, by considering the overall efficiency of the CHP + National grid system, the energy efficiency is 6% higher in the case of dynamic compared to a static design, resulting in better overall use of resources with a possible lower level of environmental impact. Moreover, the CHP plant designed with the proposed method generates electrical energy which appropriately matches that required by the process, with a surplus/deficit less than 4%, while the classic method never covers the amount required and results in a deficit greater than 20%. Finally, the annual savings of the solution derived from the dynamic method is 12% higher than that obtained with a traditional design technique. Considering the greater absolute cost of the cogeneration plant, this dynamic approach results in more profitable annual investment margins for the company.

Energetic analysis and optimal design of a CHP plant in a frozen food processing factory through a dynamical simulation model

Leone A.;Tamborrino A.;Bianchi B.
2020-01-01

Abstract

The proper design of cogeneration plants requires the choice of the technologies that best fits the ratio between heating and power loads. In this paper, a dynamical procedure of selecting and dimensioning a cogeneration plant, using deep and detailed energy, exergy and economic analysis of the entire production process of a frozen food production factory is proposed. The results highlight that a design method, based on a dynamic simulation, optimizes the energy efficiency of the food processing plant involved in the experimental test. Indeed, by considering the overall efficiency of the CHP + National grid system, the energy efficiency is 6% higher in the case of dynamic compared to a static design, resulting in better overall use of resources with a possible lower level of environmental impact. Moreover, the CHP plant designed with the proposed method generates electrical energy which appropriately matches that required by the process, with a surplus/deficit less than 4%, while the classic method never covers the amount required and results in a deficit greater than 20%. Finally, the annual savings of the solution derived from the dynamic method is 12% higher than that obtained with a traditional design technique. Considering the greater absolute cost of the cogeneration plant, this dynamic approach results in more profitable annual investment margins for the company.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/327476
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? ND
social impact