An inter‐laboratory comparison (ILC) was organized with the aim to set up quality control indicators suitable for multi component quantitative analysis by nuclear magnetic resonance (NMR) spectroscopy. 36 NMR data sets (corresponding to 1260 NMR spectra) were produced by 30 participants using 34 NMR spectrometers. The calibration line method was chosen for the quantification of a five‐component model mixture. Results show that quantitative NMR is a robust quantification tool and that 26 out of 36 data sets resulted in statistically equivalent calibration lines for all the NMR signals considered in the quantification. The performance of each laboratory was assessed by means of a new performance index (named Qp‐score) which is related to the difference between the experimental and the consensus values of the slope of the calibration lines. Laboratories endowed with Qp‐score falling within the suitable acceptability range are qualified to produce NMR spectra that can be considered statistically equivalent in terms of relative intensities of the signals. In addition, the specific response of nuclei to the experimental excitation/relaxation conditions was addressed by means of the parameter named NR. NR is related to difference between the theoretical and the consensus slopes of the calibration lines and is specific for each signal produced by a well‐defined set of acquisition parameters.

Performance Assessment in Fingerprinting and Multi Component Quantitative NMR Analyses

ARNESANO, FABIO;COLAFEMMINA, Giuseppe;DE PASCALI, SANDRA ANGELICA;LONGOBARDI, FRANCESCO;
2015-01-01

Abstract

An inter‐laboratory comparison (ILC) was organized with the aim to set up quality control indicators suitable for multi component quantitative analysis by nuclear magnetic resonance (NMR) spectroscopy. 36 NMR data sets (corresponding to 1260 NMR spectra) were produced by 30 participants using 34 NMR spectrometers. The calibration line method was chosen for the quantification of a five‐component model mixture. Results show that quantitative NMR is a robust quantification tool and that 26 out of 36 data sets resulted in statistically equivalent calibration lines for all the NMR signals considered in the quantification. The performance of each laboratory was assessed by means of a new performance index (named Qp‐score) which is related to the difference between the experimental and the consensus values of the slope of the calibration lines. Laboratories endowed with Qp‐score falling within the suitable acceptability range are qualified to produce NMR spectra that can be considered statistically equivalent in terms of relative intensities of the signals. In addition, the specific response of nuclei to the experimental excitation/relaxation conditions was addressed by means of the parameter named NR. NR is related to difference between the theoretical and the consensus slopes of the calibration lines and is specific for each signal produced by a well‐defined set of acquisition parameters.
File in questo prodotto:
File Dimensione Formato  
2015 Analytical Chemistry 89(2015)6709-6717 (ILC-NMR).pdf

non disponibili

Tipologia: Documento in Versione Editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.3 MB
Formato Adobe PDF
1.3 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Performance.pdf

accesso aperto

Tipologia: Documento in Pre-print
Licenza: Creative commons
Dimensione 589.71 kB
Formato Adobe PDF
589.71 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/147606
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 38
social impact