Polycrystalline diamond films with a thickness of about 2 μm were deposited by chemical vapour deposition on silicon substrates in continuous and pulsed wave regimes with duty cycle between 25% and 100%. The thermoluminescent behaviour of these films was analysed in the temperature range 323–723 K after β irradiation with doses in the range 7–107 Gy. All the films exhibit a dosimetric peak centred at about 592 K, showing a good linearity in the whole investigated dose range. The thermoluminescence analyses show that the intensity of the dosimetric peak is maximum for the continuous wave film, while it decreases for the pulsed wave samples. The variation of the crystalline quality and the purity of the films with the employed duty cycle, investigated via micro-Raman spectroscopy and room-temperature photoluminescence, indicates that the continuous wave (duty cycle=100%) film has the best quality, corresponding to the highest thermoluminescence efficiency.

Thermoluminescent response of thin (2 microm) polycristalline diamond films grown by pulsed and continuous microwave plasmas

SCHIAVULLI, Luigi;
2010-01-01

Abstract

Polycrystalline diamond films with a thickness of about 2 μm were deposited by chemical vapour deposition on silicon substrates in continuous and pulsed wave regimes with duty cycle between 25% and 100%. The thermoluminescent behaviour of these films was analysed in the temperature range 323–723 K after β irradiation with doses in the range 7–107 Gy. All the films exhibit a dosimetric peak centred at about 592 K, showing a good linearity in the whole investigated dose range. The thermoluminescence analyses show that the intensity of the dosimetric peak is maximum for the continuous wave film, while it decreases for the pulsed wave samples. The variation of the crystalline quality and the purity of the films with the employed duty cycle, investigated via micro-Raman spectroscopy and room-temperature photoluminescence, indicates that the continuous wave (duty cycle=100%) film has the best quality, corresponding to the highest thermoluminescence efficiency.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/101904
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact