Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) has emerged as a powerful tool for multi-elemental analysis across diverse sample matrices, from inorganic archaeological specimens to complex biological fluids. This study presents two representative case studies illustrating the technique’s adaptability and analytical power. In the archaeological glass analysis, high-resolution LA-ICP-MS enabled the reconstruction of raw material provenance, technological practices, and post-depositional alteration processes, revealing compositional heterogeneity, recycling practices, and insights into Mediterranean and Middle Eastern trade networks. Depth-resolved mapping allowed the distinction between surface corrosion layers and bulk glass chemistry, providing unprecedented detail on elemental mobility and protective mechanisms within altered glass. For biological matrices, specifically human serum, we evaluated the challenges posed by matrix effects and trace-level analytes. Standardization strategies included non–matrix-matched calibration with droplet volume correction, while signal enhancement was achieved through platinum nanoparticles (Pt NPs) produced by pulsed laser ablation in liquid. Pt NPs improved analyte ionization and signal-to-noise ratios, allowing the reliable detection of essential and toxic elements at low-ppb concentrations. Comparative studies with LIBS highlighted the advantages of nanoparticle-assisted LA-ICP-MS in sensitivity, precision, and spatial resolution. Collectively, these investigations demonstrate that LA-ICP-MS, particularly when coupled with integrative workflows and nanoparticle-based signal enhancement, provides a versatile, high-sensitivity platform for both archaeological and bioanalytical applications, offering critical insights into material provenance, technological choices, and trace metal exposure.

Approcci integrativi alla laser ablation ICP-MS: miglioramento della fedeltà del segnale e dell’accuratezza dell’imaging su materiali eterogenei / Chiurlia, C.. - (2026 Feb 20).

Approcci integrativi alla laser ablation ICP-MS: miglioramento della fedeltà del segnale e dell’accuratezza dell’imaging su materiali eterogenei

CHIURLIA, CINZIA
2026-02-20

Abstract

Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) has emerged as a powerful tool for multi-elemental analysis across diverse sample matrices, from inorganic archaeological specimens to complex biological fluids. This study presents two representative case studies illustrating the technique’s adaptability and analytical power. In the archaeological glass analysis, high-resolution LA-ICP-MS enabled the reconstruction of raw material provenance, technological practices, and post-depositional alteration processes, revealing compositional heterogeneity, recycling practices, and insights into Mediterranean and Middle Eastern trade networks. Depth-resolved mapping allowed the distinction between surface corrosion layers and bulk glass chemistry, providing unprecedented detail on elemental mobility and protective mechanisms within altered glass. For biological matrices, specifically human serum, we evaluated the challenges posed by matrix effects and trace-level analytes. Standardization strategies included non–matrix-matched calibration with droplet volume correction, while signal enhancement was achieved through platinum nanoparticles (Pt NPs) produced by pulsed laser ablation in liquid. Pt NPs improved analyte ionization and signal-to-noise ratios, allowing the reliable detection of essential and toxic elements at low-ppb concentrations. Comparative studies with LIBS highlighted the advantages of nanoparticle-assisted LA-ICP-MS in sensitivity, precision, and spatial resolution. Collectively, these investigations demonstrate that LA-ICP-MS, particularly when coupled with integrative workflows and nanoparticle-based signal enhancement, provides a versatile, high-sensitivity platform for both archaeological and bioanalytical applications, offering critical insights into material provenance, technological choices, and trace metal exposure.
20-feb-2026
LA-ICP-MS; analisi elementare; Mappe depth-resolved; enhancement segnale; concentrazioni ppb
LA-ICP-MS; elemental analysis; Depth-resolved maps; Signal enhancement; Low-ppb detection
Approcci integrativi alla laser ablation ICP-MS: miglioramento della fedeltà del segnale e dell’accuratezza dell’imaging su materiali eterogenei / Chiurlia, C.. - (2026 Feb 20).
File in questo prodotto:
File Dimensione Formato  
tesi dottorato Chiurlia con frontespizio firmato_pdfA.pdf

accesso aperto

Descrizione: Integrative Approaches to Laser Ablation ICP-MS: Enhancing Signal Fidelity and Imaging Accuracy Across Diverse Materials
Tipologia: Tesi di dottorato
Dimensione 18.05 MB
Formato Adobe PDF
18.05 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/604585
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact