We present a measurement of the parameters of the Upsilon(10580) resonance based on a dataset collected with the BABAR detector at the SLAC PEP-II asymmetric B factory. We measure the total width Gamma(tot)=(20.7 +/- 1.6 +/- 2.5) MeV, the electronic partial width Gamma(ee)=(0.321 +/- 0.017 +/- 0.029) keV and the mass M=(10579.3 +/- 0.4 +/- 1.2) MeV/c(2).

Measurement of the total width, the electronic width, and the mass of the Upsilon(10580) resonance

PALANO, Antimo;POMPILI, ALEXIS
2005-01-01

Abstract

We present a measurement of the parameters of the Upsilon(10580) resonance based on a dataset collected with the BABAR detector at the SLAC PEP-II asymmetric B factory. We measure the total width Gamma(tot)=(20.7 +/- 1.6 +/- 2.5) MeV, the electronic partial width Gamma(ee)=(0.321 +/- 0.017 +/- 0.029) keV and the mass M=(10579.3 +/- 0.4 +/- 1.2) MeV/c(2).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/59499
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 0
social impact