A compact and portable beam telescope has been built using four 1.92 x 1.92 cm(2) double sided silicon microstrip detectors with 50 mu m read-out pitch. Tests using 50 GeV pions have shown that the beam position can be defined with a precision of 5 and 7 mu m on the p-side and n-side respectively with an overall detection efficiency of 93.0%.

A high resolution beam telescope built with double sided silicon strip detectors

DE PALMA, Mauro;SELVAGGI, Giovanna;
1996-01-01

Abstract

A compact and portable beam telescope has been built using four 1.92 x 1.92 cm(2) double sided silicon microstrip detectors with 50 mu m read-out pitch. Tests using 50 GeV pions have shown that the beam position can be defined with a precision of 5 and 7 mu m on the p-side and n-side respectively with an overall detection efficiency of 93.0%.