: Background: Neoadjuvant chemotherapy (NAC) is currently used for treating breast cancer in selected cases. Our study aims to evaluate the role of automated breast ultrasound (ABUS) in the assessment of response to NAC and compare the ABUS results with MRI. Methods: A total of 52 consecutive patients were included in this study. ABUS and MRI sensitivity (SE), specificity (SP), diagnostic accuracy (DA), positive predictive value (PPV), and negative predictive value (NPV) were calculated and represented using Area Under ROC Curve (ROC) analysis, searching for any significant difference (p < 0.05). The McNemar test was used searching for any significant difference in terms of sensitivity by comparing the ABUS and MRI results. The inter-observer agreement between the readers in evaluating the response to NAC for both MRI and ABUS was calculated using Cohen's kappa k coefficient. Results: A total of 35 cases of complete response and 17 cases of persistent disease were found. MRI showed SE, SP, DA, PPV, and NPV values of 100%, 88%, 92%, 81%, and 100%, respectively, with an AUC value of 0.943 (p < 0.0001). ABUS showed SE, SP, DA, PPV, and NPV values of 88%, 94%, 92%, 89%, and 94%, respectively, with an AUC of 0.913 (p < 0.0001). The McNemar test revealed no significant difference (p = 0.1250). The inter-observer agreement between the two readers in evaluating the response to NAC for MRI and ABUS was, respectively, 0.88 and 0.89. Conclusions: Automatic breast ultrasound represents a new accurate, tri-dimensional and operator-independent tool for evaluating patients referred to NAC.

Automated Breast Ultrasound for Evaluating Response to Neoadjuvant Therapy: A Comparison with Magnetic Resonance Imaging

Telegrafo, Michele;Gurrado, Angela;Cofone, Federico;Maruccia, Michele;Stabile Ianora, Amato Antonio;Moschetta, Marco
2024-01-01

Abstract

: Background: Neoadjuvant chemotherapy (NAC) is currently used for treating breast cancer in selected cases. Our study aims to evaluate the role of automated breast ultrasound (ABUS) in the assessment of response to NAC and compare the ABUS results with MRI. Methods: A total of 52 consecutive patients were included in this study. ABUS and MRI sensitivity (SE), specificity (SP), diagnostic accuracy (DA), positive predictive value (PPV), and negative predictive value (NPV) were calculated and represented using Area Under ROC Curve (ROC) analysis, searching for any significant difference (p < 0.05). The McNemar test was used searching for any significant difference in terms of sensitivity by comparing the ABUS and MRI results. The inter-observer agreement between the readers in evaluating the response to NAC for both MRI and ABUS was calculated using Cohen's kappa k coefficient. Results: A total of 35 cases of complete response and 17 cases of persistent disease were found. MRI showed SE, SP, DA, PPV, and NPV values of 100%, 88%, 92%, 81%, and 100%, respectively, with an AUC value of 0.943 (p < 0.0001). ABUS showed SE, SP, DA, PPV, and NPV values of 88%, 94%, 92%, 89%, and 94%, respectively, with an AUC of 0.913 (p < 0.0001). The McNemar test revealed no significant difference (p = 0.1250). The inter-observer agreement between the two readers in evaluating the response to NAC for MRI and ABUS was, respectively, 0.88 and 0.89. Conclusions: Automatic breast ultrasound represents a new accurate, tri-dimensional and operator-independent tool for evaluating patients referred to NAC.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/515960
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact