Many metabolomic applications use gas chromatography/mass spectrometry (GC/MS) under standard 70 eV electron ionization (El) parameters. However, the abundance of molecular ions is often extremely low, impeding the calculation of elemental compositions for the identification of unknown compounds. On changing the beam-steering voltage of the ion source, the relative abundances of molecular ions at 70 eV El were increased up to ten-fold for alkanes, fatty acid methyl esters and trimethylsilylated metabolites, concomitant with 2-fold absolute increases in ion intensities. We have compared the abundance, mass accuracy and isotope ratio accuracy of molecular species in El with those in chemical ionization (CI) with methane as reagent gas under high-mass tuning. Thirty-three peaks of a diverse set of trimethylsilylated metabolites were analyzed in triplicate, resulting in 342 ion species ([M+H](+), [M-CH(3)](+) for CI and [M](+), [M-CH(3)](+center dot) for EI). On average, CI yielded 8-fold more intense molecular species than El. Using internal recalibration, average mass errors of 1.8 +/- 1.6 mm/z units and isotope ratio errors of 2.3 +/- 2.0% (A+1/A ratio) and 1.7 +/- 1.8% (A+2/A ratio) were obtained. When constraining lists of calculated elemental compositions by chemical and heuristic rules using the Seven Golden Rules algorithm and PubChem queries, the correct formula was retrieved as top hit in 60% of the cases and within the top-3 hits in 80% of the cases.

Determination of elemental compositions by gas chromatography/time of flight mass spectrometry using chemical and electron ionization

CATALDI, Tommaso;
2010-01-01

Abstract

Many metabolomic applications use gas chromatography/mass spectrometry (GC/MS) under standard 70 eV electron ionization (El) parameters. However, the abundance of molecular ions is often extremely low, impeding the calculation of elemental compositions for the identification of unknown compounds. On changing the beam-steering voltage of the ion source, the relative abundances of molecular ions at 70 eV El were increased up to ten-fold for alkanes, fatty acid methyl esters and trimethylsilylated metabolites, concomitant with 2-fold absolute increases in ion intensities. We have compared the abundance, mass accuracy and isotope ratio accuracy of molecular species in El with those in chemical ionization (CI) with methane as reagent gas under high-mass tuning. Thirty-three peaks of a diverse set of trimethylsilylated metabolites were analyzed in triplicate, resulting in 342 ion species ([M+H](+), [M-CH(3)](+) for CI and [M](+), [M-CH(3)](+center dot) for EI). On average, CI yielded 8-fold more intense molecular species than El. Using internal recalibration, average mass errors of 1.8 +/- 1.6 mm/z units and isotope ratio errors of 2.3 +/- 2.0% (A+1/A ratio) and 1.7 +/- 1.8% (A+2/A ratio) were obtained. When constraining lists of calculated elemental compositions by chemical and heuristic rules using the Seven Golden Rules algorithm and PubChem queries, the correct formula was retrieved as top hit in 60% of the cases and within the top-3 hits in 80% of the cases.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/49867
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 51