Background: The major limitation to the Ross operation is a progressive autograft dilation, possibly leading to reoperations. A murine model was created to evaluate pulmonary artery graft (PAG) adaptation to pressure overload. Methods: Lewis rats (n = 17) underwent heterotopic surgical implantation of a PAG, harvested from syngeneic animals (n = 17). A group of sham animals (n = 7) was used as a control. Seriated ultrasound studies of the PAG were performed. Animals were sacrificed at 1 week (n = 5) or 2 months (n = 15) and the PAG underwent mechanical and histopathological analyses. Results: Echography showed an initial increase in diameter (p < 0.001) and a decrease in peak systolic velocity (PSV). Subsequently, despite no change in diameter, an increase in PSV was observed (p < 0.01). After 1 week, the stiffness of the PAG and the aorta were similar, while at 2 months, the PAG appeared more rigid (p < 0.05). PAG’s histological analysis at 2 months revealed intimal hyperplasia development. The tunica media showed focal thinning of the elastic lamellae and normally distributed smooth muscle cells. Conclusions: We demonstrated a stiffening of the PAG wall after its implantation in systemic position; the development of intimal hyperplasia and the thinning of the elastic lamellae could be the possible underlying mechanism.

Mechanical and Structural Adaptation of the Pulmonary Root after Ross Operation in a Murine Model

Padalino M;
2022-01-01

Abstract

Background: The major limitation to the Ross operation is a progressive autograft dilation, possibly leading to reoperations. A murine model was created to evaluate pulmonary artery graft (PAG) adaptation to pressure overload. Methods: Lewis rats (n = 17) underwent heterotopic surgical implantation of a PAG, harvested from syngeneic animals (n = 17). A group of sham animals (n = 7) was used as a control. Seriated ultrasound studies of the PAG were performed. Animals were sacrificed at 1 week (n = 5) or 2 months (n = 15) and the PAG underwent mechanical and histopathological analyses. Results: Echography showed an initial increase in diameter (p < 0.001) and a decrease in peak systolic velocity (PSV). Subsequently, despite no change in diameter, an increase in PSV was observed (p < 0.01). After 1 week, the stiffness of the PAG and the aorta were similar, while at 2 months, the PAG appeared more rigid (p < 0.05). PAG’s histological analysis at 2 months revealed intimal hyperplasia development. The tunica media showed focal thinning of the elastic lamellae and normally distributed smooth muscle cells. Conclusions: We demonstrated a stiffening of the PAG wall after its implantation in systemic position; the development of intimal hyperplasia and the thinning of the elastic lamellae could be the possible underlying mechanism.
File in questo prodotto:
File Dimensione Formato  
Cattapan et al. - 2022 - Mechanical and Structural Adaptation of the Pulmonary Root after Ross Operation in a Murine Model-annotated.pdf

accesso aperto

Descrizione: articolo principale
Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 6.17 MB
Formato Adobe PDF
6.17 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/486480
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact