Background: Despite the low spatial resolution of 2D-multisegment late gadolinium enhancement (2D-MSLGE) sequences, it may be useful in uncooperative patients instead of standard 2D single segmented inversion recovery gradient echo late gadolinium enhancement sequences (2D-SSLGE). The aim of the study is to assess the feasibility and comparison of 2D-MSLGE reconstructed with artificial intelligence reconstruction deep learning noise reduction (NR) algorithm compared to standard 2D-SSLGE in consecutive patients with ischemic cardiomyopathy (ICM). Methods: Fifty-seven patients with known ICM referred for a clinically indicated CMR were enrolled in this study. 2D-MSLGE were reconstructed using a growing level of NR (0%,25%,50%,75%and 100%). Subjective image quality, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were evaluated in each dataset and compared to standard 2D-SSLGE. Moreover, diagnostic accuracy, LGE mass and scan time were compared between 2D-MSLGE with NR and 2D-SSLGE. Results: The application of NR reconstruction ≥50% to 2D-MSLGE provided better subjective image quality, CNR and SNR compared to 2D-SSLGE (p < 0.01). The best compromise in terms of subjective and objective image quality was observed for values of 2D-MSLGE 75%, while no differences were found in terms of LGE quantification between 2D-MSLGE versus 2D-SSLGE, regardless the NR applied. The sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 2D-MSLGE NR 75% were 87.77%,96.27%,96.13%,88.16% and 94.22%, respectively. Time of acquisition of 2D-MSLGE was significantly shorter compared to 2D-SSLGE (p < 0.01). Conclusion: When compared to standard 2D-SSLGE, the application of NR reconstruction to 2D-MSLGE provides superior image quality with similar diagnostic accuracy.

Feasibility of late gadolinium enhancement (LGE) in ischemic cardiomyopathy using 2D-multisegment LGE combined with artificial intelligence reconstruction deep learning noise reduction algorithm

Guaricci A. I.;
2021-01-01

Abstract

Background: Despite the low spatial resolution of 2D-multisegment late gadolinium enhancement (2D-MSLGE) sequences, it may be useful in uncooperative patients instead of standard 2D single segmented inversion recovery gradient echo late gadolinium enhancement sequences (2D-SSLGE). The aim of the study is to assess the feasibility and comparison of 2D-MSLGE reconstructed with artificial intelligence reconstruction deep learning noise reduction (NR) algorithm compared to standard 2D-SSLGE in consecutive patients with ischemic cardiomyopathy (ICM). Methods: Fifty-seven patients with known ICM referred for a clinically indicated CMR were enrolled in this study. 2D-MSLGE were reconstructed using a growing level of NR (0%,25%,50%,75%and 100%). Subjective image quality, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were evaluated in each dataset and compared to standard 2D-SSLGE. Moreover, diagnostic accuracy, LGE mass and scan time were compared between 2D-MSLGE with NR and 2D-SSLGE. Results: The application of NR reconstruction ≥50% to 2D-MSLGE provided better subjective image quality, CNR and SNR compared to 2D-SSLGE (p < 0.01). The best compromise in terms of subjective and objective image quality was observed for values of 2D-MSLGE 75%, while no differences were found in terms of LGE quantification between 2D-MSLGE versus 2D-SSLGE, regardless the NR applied. The sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 2D-MSLGE NR 75% were 87.77%,96.27%,96.13%,88.16% and 94.22%, respectively. Time of acquisition of 2D-MSLGE was significantly shorter compared to 2D-SSLGE (p < 0.01). Conclusion: When compared to standard 2D-SSLGE, the application of NR reconstruction to 2D-MSLGE provides superior image quality with similar diagnostic accuracy.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0167527321013358-main.pdf

non disponibili

Tipologia: Documento in Versione Editoriale
Licenza: Copyright dell'editore
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/480945
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
social impact