Atomic spin sensors offer precision measurements using compact microfabricated packages, placing them in a competitive position for both market and research applications. The performance of these sensors, such as the dynamic range, may be enhanced through magnetic field control. In this work, we discuss the design of miniature coils for three-dimensional localized field control by direct placement around the sensor, as a flexible and compact alternative to global approaches used previously. Coils are designed on biplanar surfaces using a stream-function approach and then fabricated using standard printed-circuit techniques. Application to a laboratory-scale optically pumped magnetometer of sensitivity approximately 20fT/Hz is shown. We also demonstrate the performance of a coil set measuring 7×17×17mm3 that is optimized specifically for magnetoencephalography, where multiple sensors are operated in close proximity to one another. Characterization of the field profile using 87Rb free-induction spectroscopy and other techniques show >96% field homogeneity over the target volume of a MEMS vapor cell and a compact stray-field contour of approximately 1% at 20 mm from the center of the cell.

Miniature Biplanar Coils for Alkali-Metal-Vapor Magnetometry

Lucivero V. G.;
2022-01-01

Abstract

Atomic spin sensors offer precision measurements using compact microfabricated packages, placing them in a competitive position for both market and research applications. The performance of these sensors, such as the dynamic range, may be enhanced through magnetic field control. In this work, we discuss the design of miniature coils for three-dimensional localized field control by direct placement around the sensor, as a flexible and compact alternative to global approaches used previously. Coils are designed on biplanar surfaces using a stream-function approach and then fabricated using standard printed-circuit techniques. Application to a laboratory-scale optically pumped magnetometer of sensitivity approximately 20fT/Hz is shown. We also demonstrate the performance of a coil set measuring 7×17×17mm3 that is optimized specifically for magnetoencephalography, where multiple sensors are operated in close proximity to one another. Characterization of the field profile using 87Rb free-induction spectroscopy and other techniques show >96% field homogeneity over the target volume of a MEMS vapor cell and a compact stray-field contour of approximately 1% at 20 mm from the center of the cell.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/477507
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 20
social impact