Background: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. Aims: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. Methods: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. Results: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. Conclusion: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.

Single suture-mediated closure system after transfemoral transcatheter aortic valve implantation: A single-center real-world experience

Iacovelli, Fortunato;Burattini, Osvaldo;Cafaro, Alessandro;Bortone, Alessandro Santo
Validation
;
Pignatelli, Antonio;
2024-01-01

Abstract

Background: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. Aims: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. Methods: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. Results: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. Conclusion: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/471938
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact