The diagnosis of Crohn’s Disease (CD) is based on a combination of clinical symptoms, laboratory tests, endoscopy, and imaging data. In Small Intestine Contrast Ultrasonography (SICUS), the ingestion of a macrogol solution as an oral contrast medium may optimize image quality. We performed a meta-analysis to evaluate the diagnostic performance of SICUS for CD. A literature search was performed in August 2023. We selected only studies where SICUS was compared to a technique that allows the assessment of the whole gastrointestinal tract, such as an MRE, a CT scan, or a surgical evaluation. We estimated pooled weighted sensitivity, specificity, and likelihood ratio for positive and negative tests (PLR/NLR) of SICUS. Summary receiver operating characteristic curves (SROC) were drawn, and pooled areas under the curve (AUC) were calculated. Five studies with 325 CD patients were included. SICUS showed a pooled sensitivity for the diagnosis of 95% (95% confidence interval CI 89–99%), a specificity = 77% (95% CI 60–90%), and the AUC was 0.94. SICUS demonstrated a pooled sensitivity for strictures of 78% (95% CI 63–88%) and a specificity = 96% (95% CI 85–99%), with AUC = 0.93. For abscesses, SICUS demonstrated a pooled sensitivity of 100% (95% CI 59–100%) and a specificity of 90% (95% CI 74–98%). Fistulae were detected with a pooled sensitivity of 77% (95% CI 46–95%) and a specificity of 92% (95% CI 75–99%). SICUS demonstrated excellent diagnostic performance compared to the gold standard despite some clinical scenarios (stenosis/fistulae) showing suboptimal diagnostic effectiveness.

Small Intestinal Contrast Ultrasonography (SICUS) in Crohn’s Disease: Systematic Review and Meta-Analysis

Losurdo G.
;
De Bellis M.;Rima R.;Palmisano C. M.;Di Leo A.;Principi M.
2023-01-01

Abstract

The diagnosis of Crohn’s Disease (CD) is based on a combination of clinical symptoms, laboratory tests, endoscopy, and imaging data. In Small Intestine Contrast Ultrasonography (SICUS), the ingestion of a macrogol solution as an oral contrast medium may optimize image quality. We performed a meta-analysis to evaluate the diagnostic performance of SICUS for CD. A literature search was performed in August 2023. We selected only studies where SICUS was compared to a technique that allows the assessment of the whole gastrointestinal tract, such as an MRE, a CT scan, or a surgical evaluation. We estimated pooled weighted sensitivity, specificity, and likelihood ratio for positive and negative tests (PLR/NLR) of SICUS. Summary receiver operating characteristic curves (SROC) were drawn, and pooled areas under the curve (AUC) were calculated. Five studies with 325 CD patients were included. SICUS showed a pooled sensitivity for the diagnosis of 95% (95% confidence interval CI 89–99%), a specificity = 77% (95% CI 60–90%), and the AUC was 0.94. SICUS demonstrated a pooled sensitivity for strictures of 78% (95% CI 63–88%) and a specificity = 96% (95% CI 85–99%), with AUC = 0.93. For abscesses, SICUS demonstrated a pooled sensitivity of 100% (95% CI 59–100%) and a specificity of 90% (95% CI 74–98%). Fistulae were detected with a pooled sensitivity of 77% (95% CI 46–95%) and a specificity of 92% (95% CI 75–99%). SICUS demonstrated excellent diagnostic performance compared to the gold standard despite some clinical scenarios (stenosis/fistulae) showing suboptimal diagnostic effectiveness.
File in questo prodotto:
File Dimensione Formato  
2023 JCM metanalisi SICUS.pdf

accesso aperto

Descrizione: articolo principale
Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 2.33 MB
Formato Adobe PDF
2.33 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/469500
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 5
social impact