Cataract or refractive lens surgery, along with the implantation of multifocal intraocular lenses (MF-IOL), enables a complete range of functional far, near and intermediate vision. Refractive, diffractive and extended depth of focus (EDoF) or combination of these principles represent the technology used to obtain this multifocality. Aberrometry makes it possible to study the aberrations induced by MF-IOLs. Among the different optical principles available to measure ocular aberrations, pyramidal wavefront-based sensor (PWS) aberrometry shows the highest resolution with MF-IOLs. Retinal image quality measured by a PWS aberrometer differed significantly according to the technology of the implanted lens. Monofocal and diffractive lenses showed the highest values of far-distance retinal image quality, followed by refractive and EDoF lenses; however, retinal image quality analysed in diffractive lenses appears to be more dependent on residual refractive error. Considering this limitation, PWS-aberrometry could be used to compare diffractive lenses. Nevertheless, further studies are needed to provide additional information about the clinical retinal image quality of MF-IOLs and to help surgeons in the important preoperative selection of IOLs.

How Reliable Is Pyramidal Wavefront-Based Sensor Aberrometry in Measuring the In Vivo Optical Behaviour of Multifocal IOLs?

Scotti, Giacomo;Boscia, Francesco;Alessio, Giovanni
2023-01-01

Abstract

Cataract or refractive lens surgery, along with the implantation of multifocal intraocular lenses (MF-IOL), enables a complete range of functional far, near and intermediate vision. Refractive, diffractive and extended depth of focus (EDoF) or combination of these principles represent the technology used to obtain this multifocality. Aberrometry makes it possible to study the aberrations induced by MF-IOLs. Among the different optical principles available to measure ocular aberrations, pyramidal wavefront-based sensor (PWS) aberrometry shows the highest resolution with MF-IOLs. Retinal image quality measured by a PWS aberrometer differed significantly according to the technology of the implanted lens. Monofocal and diffractive lenses showed the highest values of far-distance retinal image quality, followed by refractive and EDoF lenses; however, retinal image quality analysed in diffractive lenses appears to be more dependent on residual refractive error. Considering this limitation, PWS-aberrometry could be used to compare diffractive lenses. Nevertheless, further studies are needed to provide additional information about the clinical retinal image quality of MF-IOLs and to help surgeons in the important preoperative selection of IOLs.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/441340
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact