New-generation devices such as Evolut and Portico have provided favorable results in patients who underwent transcatheter aortic valve implantation (TAVI) for aortic stenosis, but their comparative effectiveness remains debated, despite its relevance when envisioning TAVI in low-risk patients. We evaluated the safety and efficacy of 2 leading TAVI devices (Evolut and Portico) used by the same team of experienced TAVI operators, focusing on long-term outcomes, including major adverse events (i.e., the composite of death, stroke, myocardial infarction, major vascular complication, or major bleeding). Unadjusted and propensity score-adjusted analyses were carried out. A total of 233 patients were included, 119 (51.1%) receiving Evolut and 114 (49%) Portico. Baseline and procedural data showed significant between-device differences, including functional class, surgical risk, chronic obstructive pulmonary disease, renal function, transesophageal guidance, device size, postdilation, and procedural time (all p <0.05). Yet, acute and in-hospital outcomes were not significantly different (all p >0.05). Follow-up status was ascertained in 228 (98%) patients after 15.0 +/- 7.6 months. Unadjusted analysis showed similar rates of major adverse events, as well as the individual risk of death, stroke, myocardial infarction, major vascular complication, major bleeding, and pacemaker implantation (all p >0.05). Even at propensity score-adjusted analysis outcomes were not significantly different with Evolut and Portico (all p >0.05). In conclusion, Evolut and Portico devices yield similarly favorable results at long-term follow-up when used by experienced TAVI operators. (C) 2020 Elsevier Inc. All rights reserved.

Long-Term Follow-Up of Transcatheter Aortic Valve Implantation With Portico Versus Evolut Devices

Pepe, Martino
Investigation
;
2020-01-01

Abstract

New-generation devices such as Evolut and Portico have provided favorable results in patients who underwent transcatheter aortic valve implantation (TAVI) for aortic stenosis, but their comparative effectiveness remains debated, despite its relevance when envisioning TAVI in low-risk patients. We evaluated the safety and efficacy of 2 leading TAVI devices (Evolut and Portico) used by the same team of experienced TAVI operators, focusing on long-term outcomes, including major adverse events (i.e., the composite of death, stroke, myocardial infarction, major vascular complication, or major bleeding). Unadjusted and propensity score-adjusted analyses were carried out. A total of 233 patients were included, 119 (51.1%) receiving Evolut and 114 (49%) Portico. Baseline and procedural data showed significant between-device differences, including functional class, surgical risk, chronic obstructive pulmonary disease, renal function, transesophageal guidance, device size, postdilation, and procedural time (all p <0.05). Yet, acute and in-hospital outcomes were not significantly different (all p >0.05). Follow-up status was ascertained in 228 (98%) patients after 15.0 +/- 7.6 months. Unadjusted analysis showed similar rates of major adverse events, as well as the individual risk of death, stroke, myocardial infarction, major vascular complication, major bleeding, and pacemaker implantation (all p >0.05). Even at propensity score-adjusted analysis outcomes were not significantly different with Evolut and Portico (all p >0.05). In conclusion, Evolut and Portico devices yield similarly favorable results at long-term follow-up when used by experienced TAVI operators. (C) 2020 Elsevier Inc. All rights reserved.
File in questo prodotto:
File Dimensione Formato  
Long-Term Follow-Up of Transcatheter Aortic Valve implantation with Portico versus Evolut devices.pdf

non disponibili

Tipologia: Documento in Versione Editoriale
Licenza: Copyright dell'editore
Dimensione 721.44 kB
Formato Adobe PDF
721.44 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/425697
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 8
social impact