A compact quartz-enhanced photoacoustic sensor for ppb-level ambient NO2 detection is demonstrated, in which a high-power blue laser diode module with a small divergence angle was employed to take advantages of the directly proportional relationship between sensitivity and power, hence improving the detection sensitivity. In order to extend the stability time, a custom grooved quartz tuning fork with 800-um prong spacing is employed to avoid complex signal balance and/or optical spatial filter components. The sensor performance is optimized and assessed in terms of optical coupling, power, gas flow rate, pressure, signal linearity and stability. A minimum detectable concentration (1 sigma) of 7.3 ppb with an averaging time of 1 s is achieved, which can be further improved to be 0.31 ppb with an averaging time of 590 s. Continuous measurements covering a five-day period are performed to demonstrate the stability and robustness of the reported NO2 sensor system.

Compact quartz-enhanced photoacoustic sensor for ppb-level ambient NO2 detection by use of a high-power laser diode and a grooved tuning fork

Sampaolo, Angelo;Patimisco, Pietro;Spagnolo, Vincenzo;
2022-01-01

Abstract

A compact quartz-enhanced photoacoustic sensor for ppb-level ambient NO2 detection is demonstrated, in which a high-power blue laser diode module with a small divergence angle was employed to take advantages of the directly proportional relationship between sensitivity and power, hence improving the detection sensitivity. In order to extend the stability time, a custom grooved quartz tuning fork with 800-um prong spacing is employed to avoid complex signal balance and/or optical spatial filter components. The sensor performance is optimized and assessed in terms of optical coupling, power, gas flow rate, pressure, signal linearity and stability. A minimum detectable concentration (1 sigma) of 7.3 ppb with an averaging time of 1 s is achieved, which can be further improved to be 0.31 ppb with an averaging time of 590 s. Continuous measurements covering a five-day period are performed to demonstrate the stability and robustness of the reported NO2 sensor system.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/424069
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 25
social impact