: The increase in fatal accidents and chronic illnesses caused by hydrogen sulfide (H2S) exposure occurring in various workplaces is pushing the development of sensing systems for continuous and in-field monitoring of this hazardous gas. We report here on the design and realization of a Near-IR quartz-enhanced photoacoustic sensor (QEPAS) for H2S leaks detection. H2S QEPAS signal was measured in matrixes containing up to 1 % of methane (CH4) and nitrogen (N2) which were chosen as the laboratory model environment for leakages from oil and gas wells or various industrial processes where H2S and CH4 can leak simultaneously. An investigation of the influence of CH4 on H2S relaxation and photoacoustic generation was proposed in this work and the sensor performances were carefully assessed with respect to CH4 content in the mixture. We demonstrated the high selectivity, with no cross talk between H2S, H2O and CH4 absorption lines, high sensitivity, and fast response time of the developed sensor, achieving a minimum detection limit (MDL) of 2.5 ppm for H2S with 2 s lock-in integration time. The employed 2.6 µm laser allowed us to employ the sensor also for CH4 detection, achieving an MDL of 85 ppm. The realized QEPAS sensor lends itself to the development of a portable and compact device for industrial monitoring.

Characterization of H2S QEPAS detection in methane-based gas leaks dispersed into environment

Olivieri, Mariagrazia;Patimisco, Pietro;
2023-01-01

Abstract

: The increase in fatal accidents and chronic illnesses caused by hydrogen sulfide (H2S) exposure occurring in various workplaces is pushing the development of sensing systems for continuous and in-field monitoring of this hazardous gas. We report here on the design and realization of a Near-IR quartz-enhanced photoacoustic sensor (QEPAS) for H2S leaks detection. H2S QEPAS signal was measured in matrixes containing up to 1 % of methane (CH4) and nitrogen (N2) which were chosen as the laboratory model environment for leakages from oil and gas wells or various industrial processes where H2S and CH4 can leak simultaneously. An investigation of the influence of CH4 on H2S relaxation and photoacoustic generation was proposed in this work and the sensor performances were carefully assessed with respect to CH4 content in the mixture. We demonstrated the high selectivity, with no cross talk between H2S, H2O and CH4 absorption lines, high sensitivity, and fast response time of the developed sensor, achieving a minimum detection limit (MDL) of 2.5 ppm for H2S with 2 s lock-in integration time. The employed 2.6 µm laser allowed us to employ the sensor also for CH4 detection, achieving an MDL of 85 ppm. The realized QEPAS sensor lends itself to the development of a portable and compact device for industrial monitoring.
File in questo prodotto:
File Dimensione Formato  
151_H2S-in-CH4_-photoacoustics-2023.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 4.59 MB
Formato Adobe PDF
4.59 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/424049
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 19
social impact