We investigated the [18F]Fluciclovine PET/CT reliability in the early detection of recurrent prostate cancer (PCa) and its impact on therapeutic decision making. We retrospectively analyzed 58 [18F]Fluciclovine PET/CT scans performed to identify early PCa recurrence. Detection rate (DR) and semiquantitative analysis were evaluated in relation to biochemical and clinical–histological features. Clinical follow-up data were collected and considered as gold standard to evaluate sensitivity, specificity, accuracy, positive and negative predictive value (PPV, NPV). The impact of [18F]Fluciclovine PET/CT on clinical management was also assessed. Overall DR resulted as 66%, while DR was 53%, 28%, and 7% in prostate/bed, lymph nodes, and bone, respectively. DR significantly increased with higher PSA values (p = 0.009) and 0.45 ng/mL was identified as the optimal cut-off value. Moreover, SUVmax and SUVmean resulted significant parameters in interpreting malignant from benign findings. [18F]Fluciclovine PET/CT reached a sensitivity, specificity, PPV, NPV, and accuracy of 87.10%, 80.00%, 87.10%, 80.00%, and 84.31%, respectively. Therapeutic strategy was changed in 51% of patients. Our results support [18F]Fluciclovine PET/CT as a reliable tool for early restaging of PCa patients, especially for local recurrence detection, leading to a significant impact on clinical management. Semiquantitative analysis could improve specificity in interpreting malignant from benign lesions.

[18F]Fluciclovine PET/CT Improves the Clinical Management of Early Recurrence Prostate Cancer Patients

Nappi A. G.;Mammucci P.;Rubini D.;Lavelli V.;Sardaro A.
;
Pisani A. R.;
2022-01-01

Abstract

We investigated the [18F]Fluciclovine PET/CT reliability in the early detection of recurrent prostate cancer (PCa) and its impact on therapeutic decision making. We retrospectively analyzed 58 [18F]Fluciclovine PET/CT scans performed to identify early PCa recurrence. Detection rate (DR) and semiquantitative analysis were evaluated in relation to biochemical and clinical–histological features. Clinical follow-up data were collected and considered as gold standard to evaluate sensitivity, specificity, accuracy, positive and negative predictive value (PPV, NPV). The impact of [18F]Fluciclovine PET/CT on clinical management was also assessed. Overall DR resulted as 66%, while DR was 53%, 28%, and 7% in prostate/bed, lymph nodes, and bone, respectively. DR significantly increased with higher PSA values (p = 0.009) and 0.45 ng/mL was identified as the optimal cut-off value. Moreover, SUVmax and SUVmean resulted significant parameters in interpreting malignant from benign findings. [18F]Fluciclovine PET/CT reached a sensitivity, specificity, PPV, NPV, and accuracy of 87.10%, 80.00%, 87.10%, 80.00%, and 84.31%, respectively. Therapeutic strategy was changed in 51% of patients. Our results support [18F]Fluciclovine PET/CT as a reliable tool for early restaging of PCa patients, especially for local recurrence detection, leading to a significant impact on clinical management. Semiquantitative analysis could improve specificity in interpreting malignant from benign lesions.
File in questo prodotto:
File Dimensione Formato  
18F-Fluciclovine PET-CT Improves the Clinical Management of Early Recurrence Prostate Cancer Patients.pdf

accesso aperto

Descrizione: Article
Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 3.43 MB
Formato Adobe PDF
3.43 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/420256
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact