We present ARDESIA-16, an X-ray spectrometer based on a monolithic 16-element Silicon Drift Detector (SDD) matrix specifically designed for synchrotron applications. In this work, we describe the main design guidelines which we followed concerning the signal throughput, the energy efficiency, the energy resolution and the overall solid angle covered by detector elements. The characterization of the spectrometer has been made both with radioactive sources in a laboratory environment and with synchrotron light at the P06 beamline (DESY, Hamburg). Experimental results showed an average energy resolution at the optimum peaking time equal to 125 eV (FWHM at Mn Kα), a maximum achieved Output Count Rate (OCR) equal to 17 Mcps, an increase of the energy efficiency above 10 keV thanks to the 1 mm-thick SDD and an overall solid angle equal to 0.4 sr. Finally, we report the first X-ray fluorescence microscopy (XFM) images acquired with an ARDESIA spectrometer.

ARDESIA-16: A 16-channel SDD-based spectrometer for energy dispersive X-ray fluorescence spectroscopy

Ignazio Allegretta;
2021-01-01

Abstract

We present ARDESIA-16, an X-ray spectrometer based on a monolithic 16-element Silicon Drift Detector (SDD) matrix specifically designed for synchrotron applications. In this work, we describe the main design guidelines which we followed concerning the signal throughput, the energy efficiency, the energy resolution and the overall solid angle covered by detector elements. The characterization of the spectrometer has been made both with radioactive sources in a laboratory environment and with synchrotron light at the P06 beamline (DESY, Hamburg). Experimental results showed an average energy resolution at the optimum peaking time equal to 125 eV (FWHM at Mn Kα), a maximum achieved Output Count Rate (OCR) equal to 17 Mcps, an increase of the energy efficiency above 10 keV thanks to the 1 mm-thick SDD and an overall solid angle equal to 0.4 sr. Finally, we report the first X-ray fluorescence microscopy (XFM) images acquired with an ARDESIA spectrometer.
File in questo prodotto:
File Dimensione Formato  
Utica et al 2021.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 6.66 MB
Formato Adobe PDF
6.66 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/380285
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 16
social impact