The CP -violating weak phase ϕs and the decay width difference ΔΓs between the light and heavy Bs0 mass eigenstates are measured with the CMS detector at the LHC in a sample of 48500 reconstructed Bs0→J/ψϕ(1020)→μ+μ−K+K− events. The measurement is based on a data sample corresponding to an integrated luminosity of 96.4fb−1, collected in proton-proton collisions at s=13TeV in 2017–2018. To extract the values of ϕs and ΔΓs, a time-dependent and flavor-tagged angular analysis of the μ+μ−K+K− final state is performed. The analysis employs a dedicated tagging trigger and a novel opposite-side muon flavor tagger based on machine learning techniques. The measurement yields ϕs=−11±50(stat)±10(syst)mrad and ΔΓs=0.114±0.014(stat)±0.007(syst)ps−1, in agreement with the standard model predictions. When combined with the previous CMS measurement at s=8TeV, the following values are obtained: ϕs=−21±44(stat)±10(syst)mrad, ΔΓs=0.1032±0.0095(stat)±0.0048(syst)ps−1, a significant improvement over the 8 TeV result.

Measurement of the CP-violating phase ϕs in the Bs0→J/ψϕ(1020)→μ+μ−K+K− channel in proton-proton collisions at s=13TeV

Abbrescia M.;Colaleo A.;De Palma M.;My S.;Pompili A.;Venditti R.;
2021-01-01

Abstract

The CP -violating weak phase ϕs and the decay width difference ΔΓs between the light and heavy Bs0 mass eigenstates are measured with the CMS detector at the LHC in a sample of 48500 reconstructed Bs0→J/ψϕ(1020)→μ+μ−K+K− events. The measurement is based on a data sample corresponding to an integrated luminosity of 96.4fb−1, collected in proton-proton collisions at s=13TeV in 2017–2018. To extract the values of ϕs and ΔΓs, a time-dependent and flavor-tagged angular analysis of the μ+μ−K+K− final state is performed. The analysis employs a dedicated tagging trigger and a novel opposite-side muon flavor tagger based on machine learning techniques. The measurement yields ϕs=−11±50(stat)±10(syst)mrad and ΔΓs=0.114±0.014(stat)±0.007(syst)ps−1, in agreement with the standard model predictions. When combined with the previous CMS measurement at s=8TeV, the following values are obtained: ϕs=−21±44(stat)±10(syst)mrad, ΔΓs=0.1032±0.0095(stat)±0.0048(syst)ps−1, a significant improvement over the 8 TeV result.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0370269321001283-main.pdf

accesso aperto

Tipologia: Documento in Versione Editoriale
Licenza: Creative commons
Dimensione 984.11 kB
Formato Adobe PDF
984.11 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/376613
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 23
social impact