Percutaneous fine-needle biopsy was used to investigate thoracic and abdominal masses in the dog and cat. One hundred and thirty-two cases were included in the study; 20 cases were excluded from the comparative study due to poor cellularity or blood contamination (retrieval rate 86-8 per cent). One hundred samples (56 dogs and 44 cats) were classified by cytology as neoplastic. All the cytological diagnoses of neoplasia were confirmed by histological samples obtained either by non-surgical methods, at surgery or during postmortem examination. No false positive diagnoses of neoplasia were made. Thirty-two samples were cytologically classified as 'negative for neoplasia'. Subsequent histological examination revealed 18 true negative and 14 false negative results. The procedure had an overall 89-4 per cent (118 cases out of 132) agreement between the diagnosis of inflammatory disease versus neoplasia, with a sensitivity of 87.8 per cent, a specificity of 100 per cent, a predictive value of a positive test of 100 per cent and a predictive value of a negative test of 56.3 per cent.

Percutaneous fine-needle biopsy of deep thoracic and abdominal masses in dogs and cats

Zatelli A.;
2004-01-01

Abstract

Percutaneous fine-needle biopsy was used to investigate thoracic and abdominal masses in the dog and cat. One hundred and thirty-two cases were included in the study; 20 cases were excluded from the comparative study due to poor cellularity or blood contamination (retrieval rate 86-8 per cent). One hundred samples (56 dogs and 44 cats) were classified by cytology as neoplastic. All the cytological diagnoses of neoplasia were confirmed by histological samples obtained either by non-surgical methods, at surgery or during postmortem examination. No false positive diagnoses of neoplasia were made. Thirty-two samples were cytologically classified as 'negative for neoplasia'. Subsequent histological examination revealed 18 true negative and 14 false negative results. The procedure had an overall 89-4 per cent (118 cases out of 132) agreement between the diagnosis of inflammatory disease versus neoplasia, with a sensitivity of 87.8 per cent, a specificity of 100 per cent, a predictive value of a positive test of 100 per cent and a predictive value of a negative test of 56.3 per cent.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/333110
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 16
social impact