The aim of this study was to analyze the reliability and repeatability of identification landmarks using 3-D cephalometric software. Ten orthognathic patients were selected for this study and underwent the following protocol: 1. radiographic evaluation (CBCT technique); 2. stone casts; 3. photos; and 4. 3-D cephalometric evaluation. Twenty-one hard tissue landmarks and 14 cephalometric measurements were taken three times (T1, T2, and T3) on each patient, with an interval of one week by two experts in orthodontics (A, B). Standard deviation and Pearson's correlation coefficient were calculated to evaluate intra- and inter-observer repeatability. The results showed a strong correlation for both intra- and inter-observer Pearson's correlation coefficient (>0.7). The current preliminary study showed that the reliability and repeatability of the identification landmarks were very high if the 3-D cephalometric landmarks are defined correctly in the three planes of the space. Further evaluation is necessary to better define the 3-D cephalometric system.

Assessment of the reliability and repeatability of landmarks using 3-D cephalometric software.

CRINCOLI, Vito;
2012-01-01

Abstract

The aim of this study was to analyze the reliability and repeatability of identification landmarks using 3-D cephalometric software. Ten orthognathic patients were selected for this study and underwent the following protocol: 1. radiographic evaluation (CBCT technique); 2. stone casts; 3. photos; and 4. 3-D cephalometric evaluation. Twenty-one hard tissue landmarks and 14 cephalometric measurements were taken three times (T1, T2, and T3) on each patient, with an interval of one week by two experts in orthodontics (A, B). Standard deviation and Pearson's correlation coefficient were calculated to evaluate intra- and inter-observer repeatability. The results showed a strong correlation for both intra- and inter-observer Pearson's correlation coefficient (>0.7). The current preliminary study showed that the reliability and repeatability of the identification landmarks were very high if the 3-D cephalometric landmarks are defined correctly in the three planes of the space. Further evaluation is necessary to better define the 3-D cephalometric system.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/32518
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact