Autoantibodies against phospholipase A2 receptor (PLA2R) are a sensitive and specific marker for idiopathic membranous nephropathy (IMN). The aim of our study was to redefine the cut-off value for the measurement of anti-PLA2R autoantibody levels by an automated enzyme immunoassay, in a large single-center cohort of Italian IMN patients at the time of diagnosis. Sixty-seven consecutive incident patients, with biopsy-proven IMN, were recruited. All patients were naïve to preceding immunosuppressive therapeutic regimens. The patient population had a mean age of 57 years and included 48 males and 19 females. Also, 200 patients with other renal diseases and 36 healthy subjects were studied as controls. The anti-PLA2R autoantibody levels were measured using the commercial enzyme-linked immunosorbent assay kit at the time of renal biopsy. At a cut-off value of 2.7 RU/ml (significantly lower than the manufacturer’s recommended value of 14 RU/ml), calculated by receiver operating characteristic curves, the sensitivity and specificity of anti-PLA2R autoantibodies in the diagnosis of IMN was 88.1 and 96% respectively. The adapted cut-off value of 2.7 UI/ml increased sensitivity without affecting the specificity and it should be the recommended value for this method. Additionally our study confirmed the correlation, at baseline, between anti-PLA2R autoantibody levels and other biomarkers of disease activity.
Definition of a new cut-off for the anti-phospholipase A2 receptor (PLA2R) autoantibody immunoassay in patients affected by idiopathic membranous nephropathy
Villani, Chiara;Fumarulo, Ruggiero;Gesualdo, Loreto;
2018-01-01
Abstract
Autoantibodies against phospholipase A2 receptor (PLA2R) are a sensitive and specific marker for idiopathic membranous nephropathy (IMN). The aim of our study was to redefine the cut-off value for the measurement of anti-PLA2R autoantibody levels by an automated enzyme immunoassay, in a large single-center cohort of Italian IMN patients at the time of diagnosis. Sixty-seven consecutive incident patients, with biopsy-proven IMN, were recruited. All patients were naïve to preceding immunosuppressive therapeutic regimens. The patient population had a mean age of 57 years and included 48 males and 19 females. Also, 200 patients with other renal diseases and 36 healthy subjects were studied as controls. The anti-PLA2R autoantibody levels were measured using the commercial enzyme-linked immunosorbent assay kit at the time of renal biopsy. At a cut-off value of 2.7 RU/ml (significantly lower than the manufacturer’s recommended value of 14 RU/ml), calculated by receiver operating characteristic curves, the sensitivity and specificity of anti-PLA2R autoantibodies in the diagnosis of IMN was 88.1 and 96% respectively. The adapted cut-off value of 2.7 UI/ml increased sensitivity without affecting the specificity and it should be the recommended value for this method. Additionally our study confirmed the correlation, at baseline, between anti-PLA2R autoantibody levels and other biomarkers of disease activity.File | Dimensione | Formato | |
---|---|---|---|
Tampoia2018_Article_DefinitionOfANewCut-offForTheA.pdf
non disponibili
Tipologia:
Documento in Versione Editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
958.02 kB
Formato
Adobe PDF
|
958.02 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.