This analysis investigated factors associated with the decrease in HbA1c in patients receiving continuous subcutaneous insulin infusion (CSII) in the OpT2mise randomized trial. In this study, patients with type 2 diabetes and HbA1c >8% following multiple daily injections (MDI) optimization were randomized to receive CSII (n = 168) or MDI (n = 163) for 6 months. Patient-related and treatment-related factors associated with decreased HbA1c in the CSII arm were identified by univariate and multivariate analyses. CSII produced a significantly greater reduction in HbA1c than MDI, and the treatment difference increased with baseline HbA1c. In the CSII arm, the only factors significantly associated with decreased HbA1c were higher baseline HbA1c (P <.001), geographical region (P <.001), higher educational level (P =.012), higher total cholesterol level (P =.002), lower variability of baseline glucose values on continuous glucose monitoring (P <.001) and the decrease in average fasting self-monitored blood glucose at 6 months (P <.001). These findings suggest that CSII offers an option to improve glycemic control in a broad range of patients with type 2 diabetes in whom control cannot be achieved with MDI. OpT2mise ClinicalTrials.gov number: NCT01182493 (https://clinicaltrials.gov/).

Factors associated with improved glycemic control following continuous subcutaneous insulin infusion therapy in patients with type 2 diabetes uncontrolled with bolus-basal insulin regimens: An analysis from the OpT2mise randomized trial

Giorgino, Francesco;
2017-01-01

Abstract

This analysis investigated factors associated with the decrease in HbA1c in patients receiving continuous subcutaneous insulin infusion (CSII) in the OpT2mise randomized trial. In this study, patients with type 2 diabetes and HbA1c >8% following multiple daily injections (MDI) optimization were randomized to receive CSII (n = 168) or MDI (n = 163) for 6 months. Patient-related and treatment-related factors associated with decreased HbA1c in the CSII arm were identified by univariate and multivariate analyses. CSII produced a significantly greater reduction in HbA1c than MDI, and the treatment difference increased with baseline HbA1c. In the CSII arm, the only factors significantly associated with decreased HbA1c were higher baseline HbA1c (P <.001), geographical region (P <.001), higher educational level (P =.012), higher total cholesterol level (P =.002), lower variability of baseline glucose values on continuous glucose monitoring (P <.001) and the decrease in average fasting self-monitored blood glucose at 6 months (P <.001). These findings suggest that CSII offers an option to improve glycemic control in a broad range of patients with type 2 diabetes in whom control cannot be achieved with MDI. OpT2mise ClinicalTrials.gov number: NCT01182493 (https://clinicaltrials.gov/).
File in questo prodotto:
File Dimensione Formato  
Metzer M et al., DOM 2017.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 410.39 kB
Formato Adobe PDF
410.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/211658
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact