Context: Urinary S-phenylmercapturic acid (SPMA) and benzene (U-Ben) are usually measured at the end of the work shift (ES), although their kinetic of elimination is not clearly known. Objective: To investigate SPMA and U-Ben elimination 16 h after the ES, in 93 coke production workers exposed to low benzene concentrations. Materials and methods: Airborne benzene (A-Ben) was measured by passive samplings, while SPMA, U-Ben, methyl-tert-butyl ether (U-MTBE), cotinine (U-Cot) and creatinine were determined on urine samples collected at ES and before the beginning of the next work shift (next BS). Results: Median A-Ben concentrations were 17.2 µg/m3in the personal and 34.7 µg/m3in the stationary samplings. SPMA was always detectable, whereas U-Ben was below the limit of quantification in 26.7% of the ES and 35.6% of the next BS samples, and U-MTBE in more than the 80.0% of the samples. At both the sampling times, SPMA and U-Ben showed a positive dependence on personal A-Ben, as well as on creatinine and U-Cot values. Discussion and conclusion: SPMA and U-Ben at the next BS were dependent on the exposure to low benzene concentrations suffered in the previous work shift, prompting a reconsideration of the urine sampling time recommended by the American Conference Governmental Industrial Hygienists (ACGIH).

Biological monitoring of exposure to low concentrations of benzene in workers at a metallurgical coke production plant: new insights into S-phenylmercapturic acid and urinary benzene

Lovreglio, Piero
;
Gallo, Elisabetta;Diomede, Laura;Scaramuzzo, Pietro;Soleo, Leonardo
2018-01-01

Abstract

Context: Urinary S-phenylmercapturic acid (SPMA) and benzene (U-Ben) are usually measured at the end of the work shift (ES), although their kinetic of elimination is not clearly known. Objective: To investigate SPMA and U-Ben elimination 16 h after the ES, in 93 coke production workers exposed to low benzene concentrations. Materials and methods: Airborne benzene (A-Ben) was measured by passive samplings, while SPMA, U-Ben, methyl-tert-butyl ether (U-MTBE), cotinine (U-Cot) and creatinine were determined on urine samples collected at ES and before the beginning of the next work shift (next BS). Results: Median A-Ben concentrations were 17.2 µg/m3in the personal and 34.7 µg/m3in the stationary samplings. SPMA was always detectable, whereas U-Ben was below the limit of quantification in 26.7% of the ES and 35.6% of the next BS samples, and U-MTBE in more than the 80.0% of the samples. At both the sampling times, SPMA and U-Ben showed a positive dependence on personal A-Ben, as well as on creatinine and U-Cot values. Discussion and conclusion: SPMA and U-Ben at the next BS were dependent on the exposure to low benzene concentrations suffered in the previous work shift, prompting a reconsideration of the urine sampling time recommended by the American Conference Governmental Industrial Hygienists (ACGIH).
File in questo prodotto:
File Dimensione Formato  
Submission revised version.pdf

non disponibili

Tipologia: Documento in Pre-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 370.21 kB
Formato Adobe PDF
370.21 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/202879
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact