Successive versions of high speed, active silicon pixel detectors with integrated readout electronics have been developed for particle physics experiments using monolithic and hybrid technologies. Various matrices with binary output as well as a linear detector with analog output have been made. The hybrid binary matrix with 1024 cells (dimension 75 mum x 500 mum) can capture events at approximately 5 MHz and a selected event can then be read out in < 10 mus. In different beam tests at CERN a precision of 25 mum has been achieved and the efficiency was better than 99.2%. Detector thicknesses of 300 mum and 150 mum of silicon have been used. In a test with a Cd-109 source a noise level of 170 e- r.m.s. (1.4 keV fwhm) has been measured with a threshold non-uniformity of 750 e- r.m.s. Objectives of the development work are the increase of the size of detecting area without loss of efficiency, the design of an appropriate readout architecture for collider operation, the reduction of material thickness in the detector, understanding of the threshold non-uniformity, study of the sensitivity of the pixel matrices to light and low energy electrons for scintillating fiber detector readout and last but not least, the optimization of cost and yield of the pixel detectors in production.

DEVELOPMENT OF SILICON MICROPATTERN PIXEL DETECTORS

DI BARI, Domenico;
1994-01-01

Abstract

Successive versions of high speed, active silicon pixel detectors with integrated readout electronics have been developed for particle physics experiments using monolithic and hybrid technologies. Various matrices with binary output as well as a linear detector with analog output have been made. The hybrid binary matrix with 1024 cells (dimension 75 mum x 500 mum) can capture events at approximately 5 MHz and a selected event can then be read out in < 10 mus. In different beam tests at CERN a precision of 25 mum has been achieved and the efficiency was better than 99.2%. Detector thicknesses of 300 mum and 150 mum of silicon have been used. In a test with a Cd-109 source a noise level of 170 e- r.m.s. (1.4 keV fwhm) has been measured with a threshold non-uniformity of 750 e- r.m.s. Objectives of the development work are the increase of the size of detecting area without loss of efficiency, the design of an appropriate readout architecture for collider operation, the reduction of material thickness in the detector, understanding of the threshold non-uniformity, study of the sensitivity of the pixel matrices to light and low energy electrons for scintillating fiber detector readout and last but not least, the optimization of cost and yield of the pixel detectors in production.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/110096
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 19
social impact