The low molecular weight (LMW) serum proteome (<15 kDa) is the most generally informative from a medical point of view. Different sample pre-treatment approaches and devices for serum depletion in high-abundant proteins were tested in order to analyze, by MALDI-TOF-MS (both in "linear" and "reflectron" acquisition mode), the serum low molecular weight proteins/peptides. The best results in terms of detected ions number and abundance were obtained by using ultrafiltration of serum on 30 kDa molecular weight cut off membranes followed by miniaturized reverse-phase solid-phase extraction (μ-SPE) as sample pre-treatment; this procedure yielded also satisfactory within-sample and sample-to-sample repeatability (on both m/z values and peak intensity of the main observable ions). The procedure was finally applied to serum samples of breast cancer patients, and the relevant results compared to "normal" samples seem to be promising for the individuation of different profiles ("linear" and "reflectron" mode) and/or peptides capable of differentiating for malignancies ("reflectron" mode).

Impact of sample preparation in peptide/protein profiling in serum of breast cancer patients by MALDI-TOF Mass spectrometry

Aresta, A.;Calvano, C. D.;Palmisano, F.;Zambonin, C. G.
;
2008-01-01

Abstract

The low molecular weight (LMW) serum proteome (<15 kDa) is the most generally informative from a medical point of view. Different sample pre-treatment approaches and devices for serum depletion in high-abundant proteins were tested in order to analyze, by MALDI-TOF-MS (both in "linear" and "reflectron" acquisition mode), the serum low molecular weight proteins/peptides. The best results in terms of detected ions number and abundance were obtained by using ultrafiltration of serum on 30 kDa molecular weight cut off membranes followed by miniaturized reverse-phase solid-phase extraction (μ-SPE) as sample pre-treatment; this procedure yielded also satisfactory within-sample and sample-to-sample repeatability (on both m/z values and peak intensity of the main observable ions). The procedure was finally applied to serum samples of breast cancer patients, and the relevant results compared to "normal" samples seem to be promising for the individuation of different profiles ("linear" and "reflectron" mode) and/or peptides capable of differentiating for malignancies ("reflectron" mode).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/10121
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 40
social impact