An high performance liquid chromatography (HPLC)–UV method for the simultaneous determination of the free forms of mycophenolic acid (MPA) and its phenol glucuronide (MPAG) in human serum samples was developed for the first time. Chromatographic separation was performed on octadecylsilane based stationary phase in combination with a mobile phase of methanol/buffered tetrabutylammonium (TBA) salt mixture. Sample pretreatment consisted of an ultrafiltration step followed by clean-up/enrichment on a C18 solid-phase extraction (SPE) cartridge. Average recoveries of (99.7±0.2)% and (64.1±6.9)% for free MPA and MPAG, respectively, were estimated in the concentration range from 0.5 to 10 g/ml. The within-day and between-days coefficients of variation were 0.4 and 0.8% for free MPA (0.1 g/ml spiking level) and 0.8 and 1.6% for free MPAG (5 g/ml spiking level), respectively. The linear ranges for free MPA and MPAG were 0.06–1 and 0.2–10 g/ml, respectively. Detection limits of 4 and 17 ng/ml for free MPA and MPAG were estimated in spiked serum. The same HPLC method was also capable of a simultaneous determination of the total concentration of MPA and MPAG when coupled to a proper sample pretreatment step. The potential of the method is demonstrated by excretion kinetics measurement in serum of patients receiving MMF therapy.

Simultaneous determination of free mycophenolate mophetil therapy by ion-pair reversed-phase liquid chromatography with diode array UV detection

ARESTA, Antonella Maria;PALMISANO, Francesco;ZAMBONIN C. G.;
2004-01-01

Abstract

An high performance liquid chromatography (HPLC)–UV method for the simultaneous determination of the free forms of mycophenolic acid (MPA) and its phenol glucuronide (MPAG) in human serum samples was developed for the first time. Chromatographic separation was performed on octadecylsilane based stationary phase in combination with a mobile phase of methanol/buffered tetrabutylammonium (TBA) salt mixture. Sample pretreatment consisted of an ultrafiltration step followed by clean-up/enrichment on a C18 solid-phase extraction (SPE) cartridge. Average recoveries of (99.7±0.2)% and (64.1±6.9)% for free MPA and MPAG, respectively, were estimated in the concentration range from 0.5 to 10 g/ml. The within-day and between-days coefficients of variation were 0.4 and 0.8% for free MPA (0.1 g/ml spiking level) and 0.8 and 1.6% for free MPAG (5 g/ml spiking level), respectively. The linear ranges for free MPA and MPAG were 0.06–1 and 0.2–10 g/ml, respectively. Detection limits of 4 and 17 ng/ml for free MPA and MPAG were estimated in spiked serum. The same HPLC method was also capable of a simultaneous determination of the total concentration of MPA and MPAG when coupled to a proper sample pretreatment step. The potential of the method is demonstrated by excretion kinetics measurement in serum of patients receiving MMF therapy.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/46891
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 27
social impact