Performances of the Gas Gain Monitoring system of the CMS RPC muon detectors after one year of operation at the scaled down closed loop recirculation gas system are presented. The GGM is made of 12 single-gap RPC's arranged in a cosmic ray telescope, with charge readout for online monitoring of working point. Preliminary results on sensitivity to gas changes and to environmental variables will be reported on. (C) 2009 Elsevier B.V. All rights reserved.

Operational Experience of the Gas Gain Monitoring system of the CMS RPC muon detectors

ABBRESCIA, Marcello;NUZZO, Salvatore Vitale
2010-01-01

Abstract

Performances of the Gas Gain Monitoring system of the CMS RPC muon detectors after one year of operation at the scaled down closed loop recirculation gas system are presented. The GGM is made of 12 single-gap RPC's arranged in a cosmic ray telescope, with charge readout for online monitoring of working point. Preliminary results on sensitivity to gas changes and to environmental variables will be reported on. (C) 2009 Elsevier B.V. All rights reserved.