The objective of this study was to compare the effectiveness of FloSealA (R) matrix hemostatic agent with hemostatic surgical procedures and TabotampA (R) in thyroid surgery. One hundred fifty-five consecutive total thyroidectomy patients were recruited at our institution between January 2005 and December 2007. Exclusion criteria were applied. Patients were randomized to one of three hemostatic approaches: 49 received surgical procedures only, and 52 received oxidized regenerated cellulose patch (Tabotamp Fibrillar 2.5 x 5 cm) and 54 FloSeal (5,000 U/5 mL). The same surgeon performed all operations. Mean operating time was reduced in the FloSeal group (105 min) vs. surgical (133 min, p = 0.02) and vs. Tabotamp (122 min, p = 0.0003). Also, wound drain removal occurred earlier with FloSeal (p = 0.006 vs. surgical; p = 0.008 vs. Tabotamp) resulting in shorter postoperative hospital stay in the FloSeal group (p = 0.02 vs. surgical; p = 0.002 vs. Tabotamp). FloSeal matrix is an effective additional agent to conventional haemostatic procedures in thyroid surgery.

The effectiveness of FloSeal matrix hemostatic agent in thyroid surgery: a prospective, randomized, control study.

TESTINI, Mario;MARZAIOLI, Rinaldo;Gurrado A;PICCINNI, Giuseppe
2009-01-01

Abstract

The objective of this study was to compare the effectiveness of FloSealA (R) matrix hemostatic agent with hemostatic surgical procedures and TabotampA (R) in thyroid surgery. One hundred fifty-five consecutive total thyroidectomy patients were recruited at our institution between January 2005 and December 2007. Exclusion criteria were applied. Patients were randomized to one of three hemostatic approaches: 49 received surgical procedures only, and 52 received oxidized regenerated cellulose patch (Tabotamp Fibrillar 2.5 x 5 cm) and 54 FloSeal (5,000 U/5 mL). The same surgeon performed all operations. Mean operating time was reduced in the FloSeal group (105 min) vs. surgical (133 min, p = 0.02) and vs. Tabotamp (122 min, p = 0.0003). Also, wound drain removal occurred earlier with FloSeal (p = 0.006 vs. surgical; p = 0.008 vs. Tabotamp) resulting in shorter postoperative hospital stay in the FloSeal group (p = 0.02 vs. surgical; p = 0.002 vs. Tabotamp). FloSeal matrix is an effective additional agent to conventional haemostatic procedures in thyroid surgery.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/136087
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 66
  • ???jsp.display-item.citation.isi??? 61
social impact