A transition radiation detector module, 6 x 2 x 2 m(3) in size, has been developed, tested and then installed on the MACRO detector at the Gran Sasso National Laboratory. The modular structure consisting of proportional tubes interleaved with polyethylene foam radiators allows to cover a large area. This detector measures the residual energies, up to 1 TeV, of penetrating muons. We discuss the possibility to obtain more physical information from these muons by measuring their residual energy and the performances of the first module. Calibration results of prototypes operated in a test beam at the CERN P.S. are also given.

Description and performances of a transition radiation detector for a Gran Sasso underground experiment

Bellotti R;SPINELLI, Paolo;ERRIQUEZ, Onofrio;
1995-01-01

Abstract

A transition radiation detector module, 6 x 2 x 2 m(3) in size, has been developed, tested and then installed on the MACRO detector at the Gran Sasso National Laboratory. The modular structure consisting of proportional tubes interleaved with polyethylene foam radiators allows to cover a large area. This detector measures the residual energies, up to 1 TeV, of penetrating muons. We discuss the possibility to obtain more physical information from these muons by measuring their residual energy and the performances of the first module. Calibration results of prototypes operated in a test beam at the CERN P.S. are also given.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11586/114943
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact